window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'UA-136411088-1');

Specifications

Specifications2019-03-04T15:38:44+09:00

Recommended Hardware Requirement

OS Windows 8 / 10 (64bit)
CPU Intel® CoreTM i7, i9, Intel® Xeon®
Memory Standard Edition: 8GB and over
Extended Edition: 16GB and over
*Analyzable model size depends on memory size
Graphics Discrete: NVIDIA®, AMD
Integrated: Intel® IrisTM Graphics
Display Resolution 1280×1024 and over
Storage Disk space 100GB and over
*Particularly required for saving project
(Project data can be saved in external storage)

Recommended Hardware Requirement

OS
Windows 8 / 10 (64bit)
CPU
Intel® CoreTM i7, i9, Intel® Xeon®
Memory
Standard Edition: 8GB and over
Extended Edition: 16GB and over
*Analyzable model size depends on memory size
Graphics
Discrete: NVIDIA®, AMD
Integrated: Intel® IrisTM Graphics
Display
Resolution 1280×1024 and over
Storage
Disk space 100GB and over
*Particularly required for saving project
(Project data can be saved in external storage)

Recommended CT Scanning Condition

Scanning X-ray computed tomography scanner
(MRI is available only for extracting geometry)
Voltage of X-ray tube Approximately 120kV
Gantry tilt 0 degrees
Slice thickness Femur: 3mm and under, if possible 1-2mm
Spine: 2mm and under, 1mm for higher accuracy
Jawbone: 1mm and under, 0.5mm for higher accuracy
Reconstruction kernel Soft-tissue or raw data

*CT scan with bone density calibration phantom is recommended to calibrate bone density strictly.

Recommended CT Scanning Condition

Scanning
X-ray computed tomography scanner
(MRI is available only for extracting geometry)
Voltage of X-ray tube
Approximately 120kV
Gantry tilt
0 degrees
Slice thickness
Femur: 3mm and under, if possible 1-2mm
Spine: 2mm and under, 1mm for higher accuracy
Jawbone: 1mm and under, 0.5mm for higher accuracy
Reconstruction kernel
Soft-tissue or raw data

*CT scan with bone density calibration phantom is recommended to calibrate bone density strictly.

Recommended bone density calibration phantom

Product Manufacturer
QRM-BDC QRM Quality Assurance in Radiology and Medicine GmbH
B-MAS200 KYOTO KAGAKU CO.,LTD

*Automatic phantom setting is available for QRM-BDC and B-MAS200
*Other phantoms can be used by designating their rods manually.

Recommended bone density calibration phantom

QRM-BDC
QRM Quality Assurance in Radiology and Medicine GmbH
B-MAS200
KYOTO KAGAKU CO.,LTD

*Automatic phantom setting is available for QRM-BDC and B-MAS200
*Other phantoms can be used by designating their rods manually.

We use cookies to deliver our services and to help us understand how visitors use our site. If these cookies are disabled, some parts of the site will not function properly. If you agree with our use of cookies, please click "I AGREE".
I agree