Recommended Hardware Requirement

OS Windows 8 / 10 / 11  (64bit)
CPU Intel® CoreTM i7, i9, Intel® Xeon®
Memory Standard Edition: 8GB and over
Extended Edition: 16GB and over
*Analyzable model size depends on memory size
Graphics Discrete: NVIDIA®, AMD
Integrated: Intel® Integrated Graphics
*AI segmentation requires NVIDIA graphics board
Display Resolution 1280×1024 and over
Storage Disk space 100GB and over
*Particularly required for saving project
(Project data can be saved in external storage)

Recommended Hardware Requirement

OS
Windows 8 / 10 / 11 (64bit)
CPU
Intel® CoreTM i7, i9, Intel® Xeon®
Memory
Standard Edition: 8GB and over
Extended Edition: 16GB and over
*Analyzable model size depends on memory size
Graphics
Discrete: NVIDIA®, AMD
Integrated: Intel® Integrated Graphics
*AI segmentation requires NVIDIA graphics board
Display
Resolution 1280×1024 and over
Storage
Disk space 100GB and over
*Particularly required for saving project
(Project data can be saved in external storage)

Recommended CT Scanning Condition

Scanning X-ray computed tomography scanner
(MRI is available only for extracting geometry)
Voltage of X-ray tube Approximately 120kV
Gantry tilt 0 degrees
Slice thickness Femur: 1-2 mm
Spine: around 1 mm
Maxillofacial: 0.5-1 mm
Reconstruction kernel Soft-tissue or raw data

*CT scan with bone density calibration phantom is recommended to calibrate bone density strictly.

Recommended CT Scanning Condition

Scanning
X-ray computed tomography scanner
(MRI is available only for extracting geometry)
Voltage of X-ray tube
Approximately 120kV
Gantry tilt
0 degrees
Slice thickness
Femur: 1-2 mm
Spine: around 1 mm
Maxillofacial: 0.5-1 mm 
Reconstruction kernel
Soft-tissue or raw data

*CT scan with bone density calibration phantom is recommended to calibrate bone density strictly.

Recommended bone density calibration phantom

Product Manufacturer
QRM-BDC QRM Quality Assurance in Radiology and Medicine GmbH
B-MAS200 KYOTO KAGAKU CO.,LTD

*Automatic phantom setting is available for QRM-BDC and B-MAS200
*Other phantoms can be used by designating their rods manually.

Recommended bone density calibration phantom

QRM-BDC
QRM Quality Assurance in Radiology and Medicine GmbH
B-MAS200
KYOTO KAGAKU CO.,LTD

*Automatic phantom setting is available for QRM-BDC and B-MAS200
*Other phantoms can be used by designating their rods manually.